Error codes for air conditioner Daikin
| Decoding errors air conditioner Daikin | ||
| Literal meaning | Numerical value | |
| AND | 0 | Equipment breakdown warning |
| AND | 1 | Indoor module board failure |
| AND | 2 | The fan motor does not work |
| AND | 3 | Increased condensation in collection tank |
| A conditioner error Daikin | 4 | Heat exchanger broken |
| AND | 5 | Exchanger temperature too high or low |
| AND | 6 | Overheating fan motor |
| AND | 7 | No current supply to the blinds |
| AND | 8 | Mains voltage exceeded |
| A | 9 | Expansion valve board failure |
| AA | Element temperature exceeded | |
| Ah error conditioner Daikin | Clean the filters. | |
| AC | No cooling / heating | |
| AJ | Indoor module control function violated | |
| AE | Not enough water in the installation | |
| AF | Humidification function impaired | |
| C | 0 | The temperature sensor function is broken |
| C | 3 | The function of the sensor measuring the amount of condensate in the tank is broken |
| C | 4 | Internal heat exchanger temperature sensor malfunction |
| C | 5 | External heat exchanger temperature sensor malfunction |
| C | 6 | The sensor stops the fan due to overheating of the motor |
| C | 7 | Damage to the blinds motion sensor |
| C | 8 | No control over incoming mains voltage |
| C | 9 | Input thermistor is broken |
| CA | Output thermistor is broken | |
| CH error code Daikin air conditioning | Clean the indoor unit from dust. | |
| CC | The humidity sensor inside the air conditioner is broken | |
| Cj | Remote sensor failure | |
| CE | There is no connection between the remote control and the indoor unit | |
| CF | High pressure sensor failure | |
Outdoor unit error codes
| Decryption of error codes for air conditioner Daikin | ||
| Literal meaning | Numerical value | |
| E | 0 | Unit disconnected due to an accident |
| E | 1 | No communication with outdoor unit head board |
| E | 3 | Exceeded system pressure |
| E | 4 | System pressure too low |
| E | 5 | Compressor shut off due to temperature rise |
| E error code Daikin air conditioning | 6 | Compressor disconnected due to excess voltage |
| E | 7 | Fan motor stopped due to overvoltage |
| E | 8 | Voltage is too high. |
| E | 9 | Expansion valve function impaired |
| Eh | Pump stopped | |
| EC | Water temperature is too low or high. | |
| Ej | Additional block protection started | |
| Ee | Condensation increased | |
| Ef | Damage to the heating module | |
| H | 0 | Thermal sensor breakdown |
| H | 1 | Street temperature sensor breakdown |
| H | 2 | Disrupted power |
| H | 3 | Increased system pressure |
| H | 4 | Reduced system pressure |
| H | 5 | Compressor disconnected due to overload |
| H | 6 | Fan off due to motor overload |
| H | 7 | Broken input voltage distribution |
| H | 8 | The outdoor temperature is too low or too high |